Calibration Services
for Testing Equipment

ASTM E4 / ISO 7500-1 · ASTM E83 / ISO 9513 · ASTM E1012 · ISO/IEC 17025

On site calibration and verification of universal testing machines, extensometers, load cells and accessories, for TensileMill CNC and third-party testing equipment, with documentation your auditors accept. This service applies to testing equipment only; sample preparation machines are covered by preventative maintenance.

TensileMill engineer attaching a clip-on extensometer to a specimen in a universal testing machine during calibration

Calibration of existing equipment, planned around your production

Consistent, defensible test results depend on calibrated equipment. TensileMill CNC arranges calibration and verification of tensile testers, universal testing machines, load cells, extensometers and related accessories through ISO/IEC 17025 accredited calibration laboratories, and coordinates the whole visit for you: scope, scheduling, the technician, and the certificates.

Calibration visits can be combined with preventative maintenance and operator training so that one visit keeps your equipment within tolerance, audit ready and running at full capability.

Equipment certification is a separate service: if you need a new system certified or recertified to a standard, see Equipment Certification.

What we calibrate

Universal testing machines

Force verification in tension, compression or both, to ASTM E4 and ISO 7500-1, for electromechanical and servo-hydraulic frames from 50 N to 3000 kN.

Crosshead speed and displacement

Verification of crosshead travel speed and of the indicated crosshead movement or the displacement measuring system used in your test methods.

Extensometers

Calibration or verification of specimen extension measurement to ASTM E83 and ISO 9513, including clip-on, long-travel and video extensometers.

Load cells and accessories

Reference and working load cells, load strings, alignment fixtures (ASTM E1012) and the instruments that feed your test results.

Third-party equipment

Recertification programs for systems from other manufacturers, including Instron, Tinius Olsen, MTS and Zwick, so new and legacy equipment share one documentation standard.

Charpy and hardness testers

Impact testers to ASTM E23 / ISO 148-2 and hardness testers to ASTM E10, E18, E92 and E384, arranged through the same accredited partners.

Common calibration requirements for a universal testing machine

Tell us which equipment requires calibration, where it is located and what measurements need to be verified. Your coordinator will confirm the appropriate scope and prepare a quotation.

RequirementService requested
ForceVerification of force readings in tension, compression or both
SpeedVerification of crosshead travel speed
DisplacementVerification of indicated crosshead movement or the relevant displacement measuring system
ExtensometerCalibration or verification of specimen extension measurements
Other requirementsAssessment of additional instruments, accessories or verification needs
ASTM E4ISO 7500-1ASTM E83ISO 9513ASTM E1012ASTM E2309ASTM E2658ASTM E74ISO 376ASTM E23ISO 148-2ISO/IEC 17025

How it works

1

Submit your request

Submit your equipment details, location and required calibration measurements.

2

Scope and quotation

Your coordinator confirms the scope, service arrangements, documentation and quotation.

3

Approve and schedule

Approve the quotation and agree on a service date. Calibration is planned at your site unless another arrangement is confirmed.

4

Calibration and documentation

The technician completes the agreed calibration, and you receive the results and appropriate documentation for your calibration services.

Accredited calibration and documentation

Calibration services are arranged through an independent calibration laboratory accredited to ISO/IEC 17025 for the applicable measurement scope. Your quotation will confirm the measurements, ranges, standards, service arrangements and documentation.

Every job is documented so that internal audits, customer approvals and NADCAP compliance reviews can be supported without extra work on your side.

What you receive

  • Calibration certificate with traceability statement and the standards applied
  • As-found and as-left data for every verified range
  • Measurement uncertainty for each reported value
  • Calibration label and recommended due date
  • Findings and recommendations from the technician

Need your testing equipment calibrated?

Request Calibration Service

Tell us which equipment requires calibration, where it is located and what measurements need to be verified. All quotations are in USD.

Request Calibration Service

Your details


Your equipment


Calibration services required